Part Number Hot Search : 
BFS17 75F256I N5H03 SM8707E BT2907 8750A 1118S TE200A
Product Description
Full Text Search
 

To Download WRT-760DT240B-035 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 COMMUNICATIONS MODULES & SUBSYSTEMS
Path Protected, Client-Side SFP, Multi-Rate, Multi-Protocol, 3R DWDM Transponder WaveReadyTM Transponder 760
Key Features
* 1+1 protection for network optics, controlled by loss of signal (LOS) level, loss of lock, or user configurable power thresholds * Client-side SFP modules support either single-mode fiber (SMF) or multimode fiber (MMF) * Multiple protocols supported at discrete bit rates of 125 Mb/s to 3.125 Gb/s * Automatic bit-rate detection and reporting * Remote management via SNMP traps or TL1 * Network optics support 16 ITU wavelengths over distances up to 100 km without dispersion compensation or amplification * Facility loopback on both network and client sides * 3R functionality at all supported bit rates and protocols
Applications
* Wavelength services * Metro optical access overlay * Protected storage area network (SAN) and GigE extension services
The WaveReady Transponder 760 (WRT-760) is a multi-rate, multi-protocol, auto-lock transponder module that translates optical signals between a variety of client-side interfaces into a long-reach, single-mode, dense wavelength division multiplexing (DWDM) interface. This module includes path protection, small form factor pluggable (SFP) modules on the client side, loopback, and 3R (reshape, retime and re-amplify/regenerate) functionality. Built-in path protection eliminates the need for extra transponders and protection devices on protected links, a significant saving in capital expenditure. SFP modules optimized for a wide range of protocols are available for singlemode and multimode fiber. Supported protocols include 100Base-FX Ethernet, Gigabit Ethernet (GigE), ESCON, Fibre channel, FICON, and OC-3 to OC-48. Supported data rates range from 125 Mb/s to 3.125 Gb/s. The WRT-760's bit-rate and protocol independence gives service providers the flexibility to meet the shifting service demands of customers without changing installed equipment. Full 3R functionality allows multiple WRT-760 modules to be deployed in series for very long reach applications. Loopback facilitates fault isolation and troubleshooting.
Compliance
* FCC Part 15 (Class A); UL 60950 3rd Edition, December 2000; CAN/CSA-C22.2 No. 950-95; NEBS Level 3; GR-63-CORE; GR-1089-CORE; GR-78-CORE; CE; IEC 60950; ETS300-386; EN 55022 (Class B); 73/23/EEC
NORTH AMERICA: 800 498-JDSU (5378)
WORLDWIDE: +800 5378-JDSU
WEBSITE: www.jdsu.com
WRT-760
2
Point-to-Point Four-Channel Protected DWDM Link
Typical Link Budget
Parameter OC-48 Gigabit Ethernet
Minimum Rx Power -28.5 dBm -30 dBm
Total Power Budget 24.4 dB 22.9 dB
Maximum Distance 97 km 91 km
WRT-760
3
Point-to-point Single Channel Protected DWDM Link
Typical Link Budget
Parameter OC-48 Gigabit Ethernet
Minimum Rx Power -28.5 dBm -30 dBm
Total Power Budget 30 dB 28.5 dB
Maximum Distance 100 km (dispersion limited) 114 km
WRT-760
4
Network Optical Specifications
Parameter Optical Path between Transmitter and Receiver Connectors Dispersion 1 at OC-48 Optical return loss of cable plant, including any connectors Discrete reflectance between transmit and receive connectors Maximum link budget at OC-48 including dispersion Transmitter Wavelength range Frequency range (32 frequencies, 100 GHz spacing) Central frequency deviation Mean output power Extinction ratio 2 Receiver Sensitivity at 100BaseF to GE, BER=1x10-10 Sensitivity at OC-48, BER=1x10-10 Overload OSNR tolerance at BER=1x10-12 Optical path penalty on standard single-mode fiber Reflectance of receiver at receiver connector LOS activation threshold LOS deactivation threshold Protection Switching time Switch-back hold time (user configurable, default is 300 seconds)
Specifications
Maximum Minimum Maximum Minimum Typical
1800 ps/nm 24 dB 27 dB 25.5 dB 28.5 dB 1530 to 1561 nm 192.1 to 195.9 THz 100 pm -1.0 dBm 2 dBm 8.2 dB 10 dB -30 dBm -28.5 dBm -8 dBm 20 dB 3 2 dB 4 -27 dB -35 dBm -30 dBm 50 ms 3 seconds 300 seconds
Maximum Minimum Maximum Minimum Typical Minimum Minimum Minimum Minimum Maximum Maximum Typical Typical Minimum Minimum Maximum
Note: All specifications are guaranteed over the life, operating temperatures, wavelength range, and input voltage range specified. This product should be deployed in accordance with each company's deployment directives. 1. Maximum dispersion for the defined path penalty of 2 dB 2. Back-to-back measurement, 8.2 dB extinction ratio and no other signal impairments 3. With receive power of -27 dBm with no other signal impairments at EOL over all temperatures 4. Dispersion penalty only
Interface Specifications
Parameter Provisioning, operations,
Specification Via the WaveReady Communication Module 200. Remote management: SNMP and TL1 command mode through administration, maintenance JDSU Node Manager software or TL1 through telnet or command-line application or SNMP. Communication with remote modules through an embedded supervisory channel. CARD (power), MAJ/CRIT (major or critical alarm), MIN (minor alarm), LOS B, LOS D (loss of lock) LOOPBK (loopback), MGT (management). Client side ports A and B single mode or multimode fiber (SMF or MMF), SFP1 SFP2, SFP3, SFP4 or SFP5. Network side ports: C and D, SMF. CARD (power), MAJ/CRIT (major or critical alarm), MIN (minor alarm), LOS B, LOS D (loss of lock). Alarm relay open under normal operation. Relay closed when power is off and alarm is active.
Front panel LEDs Front panel ports Alarms
WRT-760
5
Other Specifications
Parameter Electrical Power consumption Supply voltage 1
Condition
Specifications
Over temperature range EOL
Typical Maximum Minimum Typical Maximum
16.5 W 20 W 38 V 48 V 60 V -40 to 85 C -5 to 55 C 0 to 95% LC 1.4 kg (3.1 pounds) 25.4 x 223.5 x 175 mm (1.0 x 6.89 x 8.8 inches) WaveReady 3500-F or fan-equipped WaveReady 3100 shelf in standard 19- or 24-inch rack
Environmental Storage temperature Ambient operating temperature Humidity Mechanical Connectorization Weight (approximate) Dimensions (W x H x D) Mounting options
-5 to 55 C short term, 96 hours continuous. No more than 15 days per year. Non-condensing
1. The DC power supply must be -48 V SELV output and certified by a nationally recognized test laboratory (NRTL)
Compatibility of Client SFPs
Protocol SMF Fiber 100Base-FX Ethernet OC-3 IR-1/STM-1 S-1.1 ESCON D1 video OC-12/STM-4 S-4.1 FICON LX single mode Fibre channel 100-SMLL-L Gigabit Ethernet 1000Base-LX Fibre channel 200-SMLL-I OC-48/STM-16 I-16 OC-48 FEC MMF Fiber 100Base-FX Ethernet ESCON FICON LX FICON SX Fibre channel 100-M5-SN-I Gigabit Ethernet 1000Base-SX
Bit Rate
SFP
125 Mb/s 155.52 Mb/s 200 Mb/s 270 Mb/s 622.08 Mb/s 1.0625 Gb/s 1.0625 Gb/s 1.250 Gb/s 2.125 Gb/s 2.48832 Gb/s 2.7 Gb/s 125 Mb/s 200 Mb/s 1.0625 Gb/s 1.0625 Gb/s 1.0625 Gb/s 1.250 Gb/s
SFP1 and SFP2 SFP1 and SFP2 SFP1 and SFP2 SFP1 and SFP2 SFP1 and SFP2 SFP1 SFP1 SFP1 SFP1 SFP1 SFP1 SFP2 SFP2 or SFP11 SFP3 or SFP11 SFP4 SFP4 SFP4
1. Due to the dual media (single-mode and multimode) support of this transmitter, fulfillment of this protocol requires a single-mode fiber offset launch mode conditioning patch cord. The offset launch mode conditioning cable lowers the launch power by 0.5 dB and incurs a similar penalty on the sensitivity.
WRT-760
6
Ordering Information
For more information on this or other products and their availability, please contact your local JDSU account manager or JDSU directly at 1-800-498-JDSU (5378) in North America and +800-5378-JDSU worldwide or via e-mail at customer.service@jdsu.com.
Sample: WRT-760DT240B-053
WRT-760DT240BCode 035 037 044 045 046 047 048 049 052 053 054 055 056 057 058 059 ITU Channel/Frequency1 193.5 THz/1549.32 nm 193.7 THz/1547.72 nm 194.4 THz/1542.14 nm 194.5 THz/1541.35 nm 194.6 THz/1540.56 nm 194.7 THz/1539.77 nm 194.8 THz/1538.98 nm 194.9 THz/1538.19 nm 195.2 THz/1535.82 nm 195.3 THz/1535.04 nm 195.4 THz/1534.25 nm 195.5 THz/1533.47 nm 195.6 THz/1532.68 nm 195.7 THz/1531.90 nm 195.8 THz/1531.12 nm 195.9 THz/1530.33 nm
1. Other channels are available upon request.
SFP Sample: WRT-SFPS12SB1310
WRT-SFP
Code S24SB1310 S12SB1310 M20SB0850 S20SB1310 Model SFP1 SFP2 SFP3 SFP4
All statements, technical information and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. The user assumes all risks and liability whatsoever in connection with the use of a product or its application. JDSU reserves the right to change at any time without notice the design, specifications, function, fit or form of its products described herein, including withdrawal at any time of a product offered for sale herein. JDSU makes no representations that the products herein are free from any intellectual property claims of others. Please contact JDSU for more information. JDSU, Waveready, and the JDSU logo are trademarks of JDS Uniphase Corporation. Other trademarks are the property of their respective holders. (c)2005 JDS Uniphase Corporation. All rights reserved. 10143106 Rev. 001 11/05 WRT760.DS.CMS.AE
NORTH AMERICA: 800 498-JDSU (5378)
WORLDWIDE: +800 5378-JDSU
WEBSITE: www.jdsu.com


▲Up To Search▲   

 
Price & Availability of WRT-760DT240B-035

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X